888集团


COSINE Tier-1 distributor Jarwey|COS8820 receive cascade gain floor is ?1 dB; COS8830 starts at 3 dB

Jarwey 31 2026-11-13 15:37:39

888集团(中国)有限公司官网 -welcome

Jarwey is a COSINE Tier-1 distributor and can help with RF transceiver selection, datasheet checks, samples, and lead time.

The receive-gain floor is the cell that gets copied wrong. In the COSINE 2025 catalog, COS8820 (sub-1 GHz) lists RX cascade gain as ?1 to 80 dB. COS8830 (2.4 GHz) lists 3 to 80 dB in that same column. Both ceilings read 80 dB. The floors are 4 dB apart. A meter or IoT link budget that keeps only “80 dB max gain” will park the sub-1 GHz floor on the 2.4 GHz SoC.

RX cascade noise figure is 5 dB on both rows. Matching NF does not make the gain window match. Product pages 1005 and 1006 print the band and “request the datasheet”; the package field says to follow the datasheet. They do not print this gain pair. The numbers below are the 2025 catalog cells. Request the datasheet from Jarwey.

The earlier band-split note already tabulated average TX power, the 1 dB compression point, IIP3, and phase noise at 1 MHz, and it mentioned EVM plus filter bandwidth in one sentence. Cascade gain was not in that table. This note leaves that table where it is.

Gain floor and noise figure sit in neighboring columns

Reading across the row, equal noise figure looks like equal gain. The floor cells disagree.

PartCatalog bandRX cascade gainRX cascade NFPage
COS8820sub-1 GHz?1 to 80 dB5 dB1005
COS88302.4 GHz3 to 80 dB5 dB1006

The shared 80 dB ceiling is the strong-signal end

AGC and the attenuator steps follow the floor. When the incoming signal is already strong, the budget uses the bottom of the window, not the 80 dB end. COS8820’s catalog floor is ?1 dB. COS8830 stops at 3 dB. The shared 5 dB cascade NF does not close that 4 dB, and it does not justify one sensitivity number for both SoCs.

Band still comes first. The catalog describes one OFDM SoC family: RF front end, LNA, PA, up/down conversion, fractional synthesizer, analog baseband, and power management, for smart meters, communication networks, IoT, and connected vehicles. Those shared blocks do not merge the two gain floors.

The analog-filter 3 dB bandwidth cells read 0.2–1.5 on COS8820 and 0.2–3 on COS8830, with no unit printed. Leave the unit for the datasheet. EVM (?30 dB versus ?23 dB), 35 dBc unwanted-sideband rejection, and the 10 dBm versus 7 dBm average-power ceilings already sit in the band-split note. The catalog gives no imported cross-reference for either part. Check the gain window on the board before treating one SoC as a stand-in for the other.

Checklist before the gain cell is copied

  1. Keep the floor with the part. COS8820 is ?1 to 80 dB. COS8830 is 3 to 80 dB.
  2. The 80 dB ceiling matches. That cell is the top of the window. The floors stay 4 dB apart.
  3. Both noise figures are 5 dB. Copy NF across. Copy the gain window from the table above, row by row.
  4. The product pages omit gain. Use the 2025 catalog, then request the datasheet from Jarwey before locking AGC steps.
  5. Filter-bandwidth cells have no unit. 0.2–1.5 and 0.2–3 are not labeled in megahertz on the catalog page.
  6. Split the band first. Sub-1 GHz stays on COS8820. 2.4 GHz stays on COS8830. TX power, compression, IIP3, and phase noise stay in the earlier note.
  7. No imported alternate is listed. Confirm the window on the board. This is an evaluation, not an unverified drop-in.

Product pages

  • COS8820 (page title: Sub-1 GHz RF transceiver; package follows the datasheet)
  • COS8830 (page title: 2.4 GHz RF transceiver; package follows the datasheet)

Send the band, the gain window, and the AGC floor to Jarwey: kerry.w@jarwey.cn · contact. Datasheet checks, samples, small lots, and lead time can be handled from there.

Previous: COSINE Tier-1 distributor Jarwey|COS8552SR Zero-Drift Op Amp Selection: Low Offset, Low Power Use Cases
Next: Gree Xinyuan Tier-1 distributor Jarwey|CD294 1000 ?F: the Φ35×60 line is 400 V; page 1034 is 450 V
Related Articles
【网站地图】