Synergy Tier-1 distributor Jarwey|SY2320FN: -60 dB at 5 MHz is crosstalk, not the off-isolation typical
Jarwey is a Synergy (Xinlijie) Tier-1 distributor and can help with the datasheet, a shortlist, small-lot samples, and lead time.
On the SY2320FN page, one feature line reads “5.0MHz典型关断隔离约-60dB,极低静态功耗”: 5.0 MHz, typical off-isolation, about -60 dB, then “very low quiescent power” in the same sentence. The datasheet cover line is “5.0兆赫时的典型断开隔离-60dB”. That line has no “about”, and it does not mention quiescent power. A separate cover bullet prints 50 ?A.
In the AC table, the +25°C typical of -60 dB is not off-isolation. The symbol is switch crosstalk, KCR, at f = 5.0 MHz into 50 Ω. Off-isolation KO at the same frequency is two rows: -35 dB typical into 1.0 kΩ//15 pF, and -56 dB typical into 50 Ω.
The same product-page bullet also says the part is 3.3 V logic compatible and lists a 20 MHz shift clock. On this sheet the 20 MHz figure is the maximum at VDD = 5.0 V. The maximum at VDD = 3.0 V is 8.0 MHz, and both typical cells are dashes. That split is already in the SY2160 / SY2320 clock note. Bleed resistance, the latch-pin name, and the standby-unit note stay in their own articles.
Where the -60 dB cell actually sits
| Read this first | SY2320FN (page 855) | SY2160 (page 856) | SY2322 (page 858) |
|---|---|---|---|
| What the page does with -60 dB | Puts “about -60 dB” on off-isolation, in the same line as quiescent power | Same “about -60 dB” on off-isolation. Crosstalk is named, with no decibel | Off-isolation is “about -57 dB”. Crosstalk is a separate “about -60 dB” |
| Cover isolation line | Typical break isolation -60 dB at 5.0 MHz. No load | The same 5.0 MHz / -60 dB isolation line | Typical off-isolation -57 dB at 5.0 MHz. Crosstalk is a separate -60 dB |
| KO, 5.0 MHz, 1.0 kΩ//15 pF | +25°C typical -35 dB. The 0°C and +70°C minimum cells are also -35 dB. Maximum cells are dashes | Same three cells, typical -35 dB | Symbol VO. Typical -53 dB at CSW=0, and -25 dB at CSW=1. Min and max are dashes |
| KO, 5.0 MHz, 50 Ω | +25°C typical -56 dB. The 0°C and +70°C minimum cells match. Maximum cells are dashes | Same three cells, typical -56 dB | Typical -57 dB at CSW=0, and -49 dB at CSW=1 |
| Crosstalk, 5.0 MHz, 50 Ω | Symbol KCR. +25°C typical -60 dB. The 0°C and +70°C minimum cells are -60 dB. Maximum cells are dashes | Same three cells, typical -60 dB | Symbol VCR. Typical -60 dB. That row does not print CSW |
| Table header | Recommended conditions, plus VDD=5.0 V, tR=tF≤5.0 ns, 50% duty cycle, CLOAD=20 pF, unless the row says otherwise. The KO and KCR rows add only frequency and load | The same header | VLL=3.3 V, VDD=5 V, LEB=0, CSW=0/1, TA=25°C. Isolation rows overwrite CSW and the load |
| What the part is | 32-channel switch. The cover gives +60 V/-60 V as a VPP/VNN example. The isolation rows do not repeat that pair | 16-channel switch on the same VPP/VNN datasheet style | 32-channel 1:2 mux, +5 V only. Not a second package of page 855 |
The AC page header says SY2320. The file on the product page is SY2320FN.pdf. The pages carry a preliminary watermark and there is no revision-history table. A footnote points the test circuits to page 5. The condition cells for KO and KCR print frequency and load only, so this note does not attach the cover’s ±60 V example to those rows.
Each temperature block is min/max, then min/typ/max, then min/max. The -35 dB, -56 dB, and -60 dB numbers sit in the +25°C typical cell and again in the 0°C and +70°C minimum cells. The maximum cells are dashes. Do not treat the minimum cell as a second typical, and do not move -60 dB from the crosstalk row onto KO.
SY2160 prints the same three typicals. Page 856 still places “about -60 dB” after off-isolation and leaves crosstalk without a number. The 35 kΩ bleed note, the LE latch-pin note, and the 3.0 V / 5.0 V clock note already exist; they are only here so those numbers are not reused as isolation.
SY2322’s cover already splits -57 dB and -60 dB, and page 858 does the same. In its AC table, -57 dB is the off-isolation typical at 5 MHz, 50 Ω, and CSW=0. The same symbol is -53 dB into 1 kΩ//15 pF at CSW=0. At CSW=1 it is -49 dB into 50 Ω and -25 dB into 1 kΩ//15 pF. Crosstalk stays -60 dB typical at 5 MHz into 50 Ω, with no CSW on that row. The sheet is Rev. 0.1, August 2023. Do not copy -57 dB back onto SY2320FN.
The order table lists device SY2320 and order code SY2320FN, in a 64-lead LGA, 9.00×9.00 mm body, 0.7 mm height, 0.50 mm pitch. The outline-page header uses the same body and pitch, and prints 0.75 mm height (max). Page 855’s package cell stops at “64-Lead LGA”. Under recommended conditions, VIH minimum is 0.9×VDD, not a fixed 3.3 V row.
Selection checklist
- Match the symbol. On the SY2320 AC table, -60 dB at 5.0 MHz into 50 Ω is KCR. The KO typicals at +25°C are -35 dB (1.0 kΩ//15 pF) and -56 dB (50 Ω).
- Cover and page omit the load. The cover says typical break isolation of -60 dB. The page adds “about” and parks quiescent power in the same line. The 50 ?A bullet is a different cover line.
- Temperature columns. The 0°C and +70°C minimums equal the +25°C typical. Maximum cells are dashes. Do not read the minimum as another typical.
- Header bias. The AC table assumes VDD=5.0 V unless a row says otherwise. The isolation and crosstalk rows add frequency and load only. They do not restate VPP/VNN.
- SY2160 is the same three rows. Page 856 also hangs -60 dB on off-isolation. Leave clock, bleed, and the latch pin to the articles already published.
- SY2322’s -57 dB has a CSW state. It matches 50 Ω at CSW=0 only. CSW=1, and the 1 kΩ//15 pF rows, are not -57 dB. It is not a drop-in outline for page 855.
- 20 MHz is not the 3.3 V cell. That maximum is at VDD=5.0 V. At VDD=3.0 V the maximum is 8.0 MHz. See the clock note. VIH minimum is 0.9×VDD.
- Two heights are printed. The order cell says 0.7 mm height. The outline header says 0.75 mm height (max). The product page prints neither. The PDF is watermarked preliminary.
- The PDF is on the product page. Pages 855, 856, and 858 each link a file. For a load-matched reading or a delivery date, ask Jarwey. Check it on the board. This is not an unverified replacement.
Product pages
- SY2320FN · SY2320FN.pdf · page text puts -60 dB on off-isolation
- SY2160 · SY2160.pdf · same three AC rows as 855
- SY2322 · SY2322.pdf · -57 dB is the 50 Ω, CSW=0 typical
Send the probe-side load, the CSW state, and the isolation you can accept: kerry.w@jarwey.cn · contact.