Gree Xinyuan Tier-1 distributor Jarwey|CD294 1000 ?F: the Φ35×60 line is 400 V; page 1034 is 450 V
Jarwey is a Gree Xinyuan Tier-1 distributor and can help with selection, datasheets, samples, and lead time.
Product page CD294-450V-1000uF prints a snap-in can, Φ35×60, and 450 V / 1000 ?F. The parameter block does not print temperature, load life, or ripple, and there is no datasheet link. In the September 2026 Gree Xinyuan capacitor booklet, the lines that print both Φ35×60 and 1000 ?F are 400 V lines. On those same two cards, 450 V / 1000 ?F is a 35×70 can.
The figures below are copied from that public booklet. They are not a measurement from the single-part datasheet. Contact Jarwey for the datasheet.
On the UPS card, Φ35×60 and 1000 ?F sit in the 400 V column
The card is titled CD293/294/295/296, under industrial power supplies for UPS. The slashes separate four family names. They are not the orderable model CD294-450V-1000uF.
The header spans 315–600 VDC and 47–1200 ?F. The temperature line is printed as ?25°C to +105 (85) °C. Load life is two lines: 2,000–5,000 h at 85°C, and 2,000–3,000 h at 105°C. The standards line cites IEC 60384 and GB/T 6346.1.
The table note says ripple is the rating at 120 Hz, and that the number before the slash is 85°C and the number after it is 105°C.
- 400 V / 1000 ?F: can 35×60, ripple 3900/2800 mA. Height and capacitance look like page 1034. The voltage does not.
- 450 V / 1000 ?F: can 35×70, ripple 3900/3500 mA. The voltage matches. The can is 10 mm taller than Φ35×60.
3900 mA is printed on both lines. On the first it is the 85°C value at 400 V in a 35×60 can. On the second it is the 85°C value at 450 V in a 35×70 can. The shared numeral is not one cell.
The can in the photo is marked 400 V / 1800 ?F, CD295, 85°C. 1800 ?F sits outside the 1200 ?F header, and the family mark is not CD294. That photo is not page 1034.
The storage card keeps the same can split, and it changes what a slash means
The next card is titled CD294K/CD296K, under PV, storage, and charging conversion. The K is part of the family name. Page 1034 has no K.
Voltage and capacitance spans match the UPS card: 315–600 VDC and 47–1200 ?F. The temperature line is ?40°C to +105°C, fifteen degrees colder at the floor. Load life is a single line, 2,000–3,000 h at 105°C. There is no 85°C / 2,000–5,000 h line. The standards line cites IEC 60384 and GB/T 2693. Sharing the IEC number does not merge this card with the UPS card, because the GB/T number is different.
The table note says ripple is rated at 105°C and 120 Hz. A slash on this card means 2,000 h and 3,000 h, not 85°C and 105°C.
- 400 V / 1000 ?F: can 35×60, ripple 2700 mA. This row has no slash. Do not split it into a 2,000 h value and a 3,000 h value, and do not average it with the UPS card's 2800 mA at 105°C.
- 450 V / 1000 ?F: can 35×70, ripple 3000 mA. This row also has no slash. The can is still not Φ35×60.
The can in the photo is marked 450 V / 820 ?F, CD294K, 105°C. That is an 820 ?F sleeve with a K. It is not the 1000 ?F part on page 1034, and it is not unsuffixed CD294.
The appliance row is the one that matches voltage, capacitance, and can together
In the home-appliance snap-in table, CD294 at 450 V / 1000 ?F is Φ35×60, ?25°C to +105°C, 2000 h in the load-life cell, and 3.50 A of ripple. The column heading states 120 Hz. It does not add a separate ripple-test temperature. Can, voltage, and capacitance match page 1034. The product page itself does not print the 3.50 A, the 2000 h, or the temperature.
3.50 A is the same numeral as 3500 mA. The UPS card also prints 3500 mA as the 105°C value of 450 V / 1000 ?F, on a 35×70 can, next to an 85°C value of 3900 mA. Same digits, different cell.
The page bullets "ripple current more than 30% above a conventional part" and "maximum temperature 125°C" sit above the whole table. They are not the 1000 ?F cell. The row that actually reaches +125°C is not CD294.
The same appliance table also lists CD294 450 V / 820 ?F at 3.00 A and CD294W 450 V / 820 ?F at 4.00 A, both in Φ35×60. That same-can split is already in the CD294 versus CD294W ripple note. Page 1035 is CD294W-450V-820uF. The CD294W series card's 450 V / 1000 ?F line is 35×70 and 4500 mA, with no frequency in the ripple column. The CD294H 125°C card has no 1000 ?F line. Both are already published. On the 3,000 h CD29H/CD298 card, 450 V / 1000 ?F is 35×80 and 3200 mA at 105°C, 120 Hz. That row belongs to the 3,000 h versus 5,000 h note. Do not paste 3200 mA onto page 1034.
Five 1000 ?F lines, one product page
| Source | Line | Can | What the ripple cell actually prints | Against the product page |
|---|---|---|---|---|
| UPS · CD293/294/295/296 | 400 V / 1000 ?F | 35×60 | 3900/2800 mA. 120 Hz; 85°C then 105°C | Can and capacitance resemble 1034. Voltage is not 450 V |
| UPS · same card | 450 V / 1000 ?F | 35×70 | 3900/3500 mA. Same 120 Hz note | Voltage matches. Height is not Φ35×60. The 3500 mA at 105°C is not the appliance 3.50 A |
| Storage · CD294K/CD296K | 400 V / 1000 ?F | 35×60 | 2700 mA. 105°C, 120 Hz. No slash on this row | Can and capacitance resemble 1034. Voltage is not 450 V. Do not average with 2800 mA |
| Storage · same card | 450 V / 1000 ?F | 35×70 | 3000 mA. 105°C, 120 Hz. No slash on this row | Voltage matches. Height is not Φ35×60. The K is not the 1034 model |
| Appliance snap-in table | CD294 450 V / 1000 ?F | Φ35×60 | 3.50 A. Column heading states 120 Hz | 1034. The parameter block does not print this 3.50 A |
Gree Xinyuan is a wholly owned subsidiary of Gree Electric. Keep each milliamp on its own row, then check the datasheet for that part number. Load life does not travel across cards either: the appliance cell is 2000 h beside ?25°C to +105°C; the UPS card prints two hour ranges; the storage card prints 2,000–3,000 h at 105°C.
Seven checks before layout
- Read voltage first. Page 1034 is 450 V. On the UPS card and the storage card, the line that pairs Φ35×60 with 1000 ?F is 400 V.
- Then read height. On both cards, 450 V / 1000 ?F is 35×70, not the Φ35×60 can on the product page.
- A slash on the UPS card is temperature. The note says 120 Hz, 85°C then 105°C. The 400 V line is 3900/2800 mA. The 450 V line is 3900/3500 mA. 3900 appears on both, at different voltage and height.
- A slash on the storage card is hours. The note says 105°C and 120 Hz, and the slash means 2,000 h versus 3,000 h. The two 1000 ?F rows above have no slash, so do not split them. Do not average 2700 mA with 2800 mA.
- 3.50 A lives only on the appliance table. The column says 120 Hz. The can is Φ35×60, the temperature cell is ?25°C to +105°C, and the life cell is 2000 h. It matches the digits of 3500 mA on the 35×70 can. It is not that cell.
- Read the sleeve. The UPS photo is CD295, 400 V / 1800 ?F. The storage photo is CD294K, 450 V / 820 ?F. Page 1034 has no K and no H.
- Datasheet and samples. Ask Jarwey for the datasheet of page 1034, then measure temperature rise and ripple on the board. This is an evaluation, not an unverified replacement.
Datasheet and product pages
- Product page: CD294 450 V / 1000 ?F snap-in
- Product page: CD294W 450 V / 820 ?F snap-in (the same-can ripple split is the earlier note, not this 1000 ?F question)
- Datasheet: contact Jarwey. kerry.w@jarwey.cn · Contact
Jarwey · Gree Xinyuan Tier-1 distributor · kerry.w@jarwey.cn · Contact.