COSINE Tier-1 distributor Jarwey|COS2975x current limit is 9.5 A typical with the output at 0 V

Jarwey 28 2026-11-18 15:36:47

888集团(中国)有限公司官网 -welcome

Jarwey is a COSINE Tier-1 distributor and can help with the datasheet, selection, samples, small lots, and lead time.

The short-circuit current limit for this high-current LDO family is the Current Limit (ILIM) row in the Rev1.3 electrical table. That row is measured at VOUT = 0 V. It is not the Iout printed on the product-page function line, and it is not the High Current Capability line on the features page.

The PDF is on the COS29752WU page. The cover reads COS2915X/2930X/2950X/2975X. The electrical-table header says VIN = VOUT + 1 V, IOUT = 10 mA, TJ = +25°C, unless otherwise noted. The current-limit row notes VOUT = 0 V on its own. The minimum cell is a dash, not zero.

Current-limit row versus the page Iout

Datasheet row Feature current Limit, typical Limit, max Product-page function line Page
COS2915x, VOUT = 0 V 1.5 A 2.0 A 2.5 A COS29152WU prints Iout 1.5A 983
COS2930x, VOUT = 0 V 3.0 A 4.0 A 4.8 A COS29302 prints Iout 3A 981
COS2950x, VOUT = 0 V 5.0 A 6.3 A 7.8 A COS29502WU prints Iout 5A 982
COS2975x, VOUT = 0 V 7.5 A 9.5 A 11.7 A COS29752WU function text prints neither 7.5A nor a current limit 863

The features page lists High Current Capability as 1.5 A for COS29150/1/2/3, 3.0 A for COS29300/1/2/3, 5.0 A for COS29500/1/2/3, and 7.5 A for COS29750/1/2/3. The four pages on the site are the adjustable suffix-2 parts, so they sit on those rows. Typical current limit sits above the feature current: 2.0 A, 4.0 A, 6.3 A, and 9.5 A. The maximum cells are 2.5 A, 4.8 A, 7.8 A, and 11.7 A. The unit is A.

The application note says current limiting is provided, the limiting is linear, and output current under overload stays constant. The maximum cell is the top of the VOUT = 0 V row. It is not a continuous output rating. Continuous current stays on the feature-current column. The Iout on pages 983, 981, and 982 matches that column. It does not match 2.0 / 4.0 / 6.3 / 9.5 A.

The COS29752WU function text talks about an intermediate bus, a low-voltage high-current rail, and digital monitoring. The page does not print 7.5 A or 9.5 A. 7.5 A is on the features page of the PDF on that product page. 9.5 A is the current-limit typical in the same PDF. The site model string for COS29302 omits WU. The package field is still TO-263-5. The datasheet order number is COS29302WU, and the current-limit row is COS2930x.

Full-load dropout, the three input-voltage readings, and full-load output capacitance already have their own notes. Those tables are not repeated here.

Checklist before you freeze the rail

  1. Match the row. COS29152WU to COS2915x, COS29302WU to COS2930x, COS29502WU to COS2950x, COS29752WU to COS2975x.
  2. Keep two currents. Feature page: 1.5 / 3.0 / 5.0 / 7.5 A. Current limit: 2.0 / 4.0 / 6.3 / 9.5 A typical, 2.5 / 4.8 / 7.8 / 11.7 A max.
  3. Condition. The limit row says VOUT = 0 V. The minimum cell is a dash. The table header junction temperature is +25°C, unless otherwise noted.
  4. Continuous current. Use the feature current. Leave the limit maximum for short-circuit stress. Do not budget it as current the regulator can deliver all day.
  5. Overload. The note says the limit is linear and the overload current stays constant. Do not rewrite that sentence as foldback.
  6. Page 863 prints neither number. The function text has no 7.5 A and no current limit. Both numbers are in the Rev1.3 PDF on that page.
  7. Where the datasheet is. Pages 983, 981, and 982 say to ask Jarwey for the datasheet. MIC29152, MIC29302, MIC29502, and MIC29752WWT are evaluation anchors. Check them on samples. This is not an unverified drop-in replacement.

Pages and the datasheet

Send the output voltage, the continuous current, and the current the wiring can stand during a short to Jarwey. Samples and small-lot lead time can be lined up against the matching current-limit row: kerry.w@jarwey.cn · contact.

Jarwey · COSINE Tier-1 distributor · datasheet, selection, samples, and lead time.

Previous: COSINE Tier-1 distributor Jarwey|COS8552SR Zero-Drift Op Amp Selection: Low Offset, Low Power Use Cases
Next: CETC Tier-1 distributor Jarwey|WM2HA040120L: 40 mΩ is measured at 33.3 A, not the 67 A on the cover
Related Articles